www.ghcable.comABC cable, ACSR Conductor, Wilding Cable, ACSR cable, AAAC cable, Single wire, Rubber Cable, Control Cable, Speaker Wire, POWER CABLE]

 

 

 

   
8
Communication Cable
8.5
PVC Insulated and PVC Sheathed Local Telephone Cable
 
Communication cable, Cat 5,Cat 6,Telephone Wire www.ghcable.com

a

Porduct introduction

 

  • The cables are designed for main communicationlines of mining Wells, streets, etc and connecting cables betwwen connecting box and telephone.

b

complied standard

 

  • GH/JT 051-2000

c

Type and description of cables

 
Type Description Application
HUVV Copper core ,PVC Insulated and sheathed mining telephone cable Laying in mining well,
for common occasion
HUVV22 Copper cor, PVC Insulated and sheathed mining telephone cable with steel tape armor
d

application Condition

 

  • The temperature of cable of cables is -40¡æ?-?+60¡æ?
  • The lowest installation temperature of cable is -5¡æ?
  • Permissive bending radius of cable should be no less than 20 times of external diameter of cable.
e

Main technical Parameter

 

  1. Conductor

 

Conductors construction and DC resistance should be in accordance with the table Following:

type of cable Specification
of conductor
Nom.
insulation
thickness
Max.DC
resistance
at 20¡æ?/td>
Min.insulation
resistance
at 20¡æ?/td>
pairs
of cable
HUVV
HUVV22
Φ0.8 0.54 40¦¸/km 40M¦¸*km 5,7,10,20,30,50,100

 

  1. Insulation

 

  • YD/T760-complied low density,middle and high density PE are adopted as insulation.
  • There are 3 colors:red, blue ,and white for insulation ,When can be natural color.
  • Nom.Value of sheath should conform to the stipulation of Table .Allow 10% minus. Tolerance for sheath thickness,but minium thickness should be not less than 85% of nominal value.

 

  1. test

 

  • Finished cable can withstand AC 50HZã€?000V when tested by voltage with standing test.

 

  1. Insulation resistance

 

  • Min insulation resistance of cable at 20¡æ?should be in accordance with the stipulation of the Table of conductor.
f

delivery

 

  • Length that is to be reeled is no less than 100m.Should two sides agree ,any length is allowed to be in delivery. The tolerance of length should be no more than +-0.5%.
Copyright: GHCABLE(Danyang Ganghong Electric Wire & Power Cable Co., Ltd)