Jiangsu Ganghong Electric Wire and Power Cable Corporation Limited

60245 IEC 66(YCW) heavy-duty tough rubber sheathed flexible cable 60℃ 450/750V

Type 60245 IEC 66(YCW)

FEATURES

450/750V

60℃

IEC60245-4, GB/T 5013.4

APPLICATION

60245 IEC 66 (YCW) heavy-duty tough rubber sheathed flexible cable is suitable for household appliances, electric tools/instrument and other various moveable electrical equipments of rated voltage up to and including 450/750V. It is also suitable for weather and oil resistance purpose.

CONSTRUCTION

Conductor

Plain or tinned copper

IEC60228, class 5 conductors

No. of conductors: 1, 2, 3, 4 or 5

Separator

Optional

Insulation

Rubber compound of Type IE4

Filler

If any

Outer Sheath

Outer Sheath

For single-conductor cable

  • Sheath in a single layer, rubber compound of type SE4

For multiple-conductor cables

  1. Cross-sections no exceeding 10mm2
  • In a single layer, rubber compound of type SE4
  1. Cross-sections in excess of 10mm2
  • Either in a single layer, rubber compound of type SE4
  • Or in two layers, with inner layer made of rubber compound SE3 and outer layer of rubber compound of type SE4

Dimensions of type 60245 IEC66 (YCW)

1 2 3 4 5 6 7
Number and Nominal cross-

Sectional area of

conductor

Thickness of insulation Thickness of sheath

Specified value

Mean overall diameter
Specified value Single

layer

Double layer Lower Limit Upper Limit
Inner Outer
mm2 mm mm mm mm mm mm
1×1.5 0.8 1.4 5.7 7.1
1×2.5 0.9 1.4 6.3 7.9
1×4 1.0 1.5 7.2 9.0
1×6 1.0 1.6 7.9 9.8
1×10 1.2 1.8 9.5 11.9
1×16 1.2 1.9 10.8 13.4
1×25 1.4 2.0 12.7 15.8
1×35 1.4 2.2 14.3 17.9
1×50 1.6 2.4 16.5 20.6
1×70 1.6 2.6 18.5 23.3
1×95 1.8 2.8 20.8 26.0
1×120 1.8 3.0 22.8 28.6
1×150 2.0 3.2 25.2 31.4
1×185 2.2 3.4 27.6 34.4
1×240 2.4 3.5 30.6 38.3
1×300 2.6 3.6 33.5 41.9
1×400 2.8 3.8 37.4 46.8
             
2×1 0.8 1.3 7.7 10.0
2×1.5 0.8 1.5 8.5 11.0
2×2.5 0.9 1.7 10.2 13.1
2×4 1.0 1.8 11.8 15.1
2×6 1.0 2.0 13.1 16.8
2×10 1.2 3.1 17.7 22.6
2×16 1.2 3.3 1.3 2.0 20.2 25.7
2×25 1.4 3.6 1.4 2.2 24.3 30.7
             
3×1 0.8 1.4 8.3 10.7
3×1.5 0.8 1.6 9.2 11.9
3×2.5 0.9 1.8 10.9 14.0
3×4 1.0 1.9 12.7 16.2
3×6 1.0 2.1 14.1 18.0
3×10 1.2 3.3 19.1 24.2
3×16 1.2 3.5 1.4 2.1 21.8 27.6
1 2 3 4 5 6 7
Number and Nominal cross-

Sectional area of

conductor

Thickness of insulation Thickness of sheath

Specified value

Mean overall diameter
Specified value Single

layer

Double layer Lower Limit Upper Limit
Inner Outer
mm2 mm mm mm mm mm mm
3×25 1.4 3.8 1.5 2.3 26.1 33.0
3×35 1.4 4.1 1.6 2.5 29.3 37.1
3×50 1.6 4.5 1.8 2.7 34.1 42.9
3×70 1.6 4.8 1.9 2.9 38.4 48.3
3×95 1.8 5.3 2.1 3.2 43.3 54.0
             
4×1 0.8 1.5 9.2 11.9
4×1.5 0.8 1.7 10.2 13.1
4×2.5 0.9 1.9 12.1 15.5
4×4 1.0 2.0 14.0 17.9
4×6 1.0 2.3 15.7 20.0
4×10 1.2 3.4 20.9 26.5
4×16 1.2 3.6 1.4 2.2 23.8 30.1
4×25 1.4 4.1 1.6 2.5 28.9 36.6
4×35 1.4 4.4 1.7 2.7 32.5 41.1
4×50 1.6 4.8 1.9 2.9 37.7 47.5
4×70 1.6 5.2 2.0 3.2 42.7 54.0
4×95 1.8 5.9 2.3 3.6 48.4 61.0
4×120 1.8 6.0 2.4 3.6 53.0 66.0
4×150 2.0 6.5 2.6 3.9 58.0 73.0
             
5×1 0.8 1.6 10.2 13.1
5×1.5 0.8 1.8 11.2 14.4
5×2.5 0.9 2.0 13.3 17.0
5×4 1.0 2.2 15.6 19.9
5×6 1.0 2.5 17.5 22.2
5×10 1.2 3.6 22.9 29.1
5×16 1.2 3.9 1.5 2.4 26.4 33.3
5×25 1.4 4.4 1.7 2.7 32.0 40.4
             
Scroll to Top