Type 60227 IEC 43
FEATURES
300/300V
70℃
IEC 60227-5
APPLICATION
Cord for indoor decorative lighting chains
CONSTRUCTION
Conductor
No. of conductors: 1
IEC 60228, class 5 conductors
Insulation
PVC compound of Type PVC/D
It shall consist of two layers and applied by dual extrusion around the conductor.
The outer layer of insulation shall be of a colour contrasting with that of the inner layer, but shall adhere to the inner layer.
The combined thickness of the inner and outer layer of insulation shall comply with the overall thickness specified in the following table, columns 3 and 4, but at no point the thickness of either layer shall be less than the value specified in column 2.
Cord identification
Preferred colour of outer layer: green
General data for type 60227 IEC 43
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 
| Nominal cross-
 sectional area of conductor  | 
Thickness of
 Each layer of Insulation  | 
Overall
 Insulation Thickness  | 
Overall
 Insulation thickness 
 Mean value  | 
Mean overall diameter | Minimum insulation
 resistance at 70℃  | 
|
| Minimum
 value  | 
Minimum
 value  | 
Lower limit | Upper limit | |||
| mm2 | mm | mm | mm | mm | mm | MΩ·km | 
| 0.5 | 0.2 | 0.6 | 0.7 | 2.3 | 2.7 | 0.014 | 
| 0.75 | 0.2 | 0.6 | 0.7 | 2.4 | 2.9 | 0.012 | 
															