Jiangsu Ganghong Electric Wire and Power Cable Corporation Limited

,

H03V2V2-F / H03V2V2H2-F

H03V2V2-F for Circular Cords & H03V2V2H2-F for Flat Cords, 300/300V, 90º C

Application
These cables are suitable for domestic premises, kitchen, office for light service or light portable apparatuses. With their special insulation and sheath compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without contact with warm parts and radiations.
Standard
HD 21.12 S1; HD 308 S2, DIN VDE 0281 part 1&12
Construction
Conductor: Bare copper fine wire, stranded to IEC 60228 class 5 and HD 383 class 5
Insulation: PVC

Color coded to VDE-0293-308 as below

2 cores – Brown, Blue
3 cores (G) – Green/Yellow, Brown, Blue
3 cores – Brown, Black, Grey
4 cores (G) – Green/Yellow, Brown, Black, Grey
4 cores – Blue,Brown, Black, Grey
5 cores (G) – Green/Yellow, Blue, Brown,  Black,Grey
5 cores – Blue, Brown, Black,  Grey, Black

Sheath: PVC
Technical Characteristics
Rated voltage: 300/300V
Test voltage: 2000V
Flexing bending radius: 15 x Ø
Static bending radius: 4 x Ø
Operating temperature: -5º C to +90º C

Technical Parameter for H03V2V2-F & H03V2V2H2-F (60227 IEC 56)

No. of Cores x Nom. Cross Sectional Area No. of wires Wire Dia. Nom. PVC Insulation Thickness Nom.PVC Sheath Thickness Approx. Overall Diameter Overall Diameter Min. Insulation Resistance at 90ºC Maximum  Resistance of Conductor at 20ºC
Min. OD Max. OD Plain Copper Wires
# x mm² mm mm mm mm mm mm Mohm.km Ω/km
H03V2V2-F (60227 IEC 56)
2 x 0.5 16 0.2 0.5 0.6 5.3 4.6 5.9 0.012 39.0
2 x 0.75 24 0.2 0.5 0.6 5.7 4.9 6.3 0.010 26.0
3 x 0.5 16 0.2 0.5 0.6 5.6 4.9 6.3 0.012 39.0
3 x 0.75 24 0.2 0.5 0.6 6.0 5.2 6.7 0.010 26.0
4 x 0.5 16 0.2 0.5 0.6 6.1 5.4 6.9 0.012 39.0
4 x 0.75 24 0.2 0.5 0.6 6.6 5.7 7.3 0.010 26.0
H03V2V2H2-F  (60227 IEC 56)
2 x 0.5 16 0.2 0.5 0.6 3.2×5.2 3.0 x 4.9 3.7 x 5.9 0.012 39.0
2 x 0.75 24 0.2 0.5 0.6 3.4×5.6 3.2 x 5.2 3.8 x 6.3 0.010 26.0