Type 60227 IEC 56
FEATURES
300/300V
90℃
IEC 60227-5
APPLICATION
Heat-resistant Light PVC sheathed cord
CONSTRUCTION
Conductor
No. of conductors: 2 and 3
IEC 60228, class 5 conductors
Insulation
PVC compound of Type PVC/E
Assembly of cores
Circular cord: the cores shall be twisted together
Flat cord: the cores shall be laid parallel.
Sheath
PVC compound of type PVC/ST 10
General data for type 60227 IEC 56
1 | 2 | 3 | 4 | 5 | 6 |
Number and nominal cross-
sectional area of conductors |
Thickness of insulation | Thickness of sheath
Specified value |
Mean overall dimensions | Minimum insulation
resistance at 70℃ |
|
Specified
value |
Lower limit | Upper limit | |||
mm2 | mm | mm | mm | mm | MΩ·km |
2 x 0.5 | 0.5 | 0.6 | 4.6
or 3.0 x 4.9 |
5.9
or 3.7 x 5.9 |
0.012 |
2 x 0.75 | 0.5 | 0.6 | 4.9
or 3.2 x 5.2 |
6.3
or 3.8 x 6.3 |
0.010 |
3 x 0.5 | 0.5 | 0.6 | 4.9 | 6.3 | 0.012 |
3 x 0.75 | 0.5 | 0.6 | 5.2 | 6.6 | 0.010 |